LMA-1800 Catalog Sheet – 063014 Designed, Manufactured and Tested in the United States of America Deflectometer is a trademark of EDI
INDUCTIVE LOOP VEHICLE DETECTOR
SINGLE CHANNEL
DUAL PROGRAMMABLE SOLID STATE OUTPUTS
PLUG-IN COMPATIBLE WITH:
o Chamberlain/Elite SL3000, CSW200
o Advanced Access Automation CSL2000, CSW2000, RSW1000
o All-O-Matic SL100-DC, SL 150DC, OH 200DC, SW 300DC, SW350DC
o Intelligate Systems IQ500, IQ5000
o Linear (OSCO) SL & SW Series with APeX controller
o SECOM Late model operators with 10-pin Molex connectors
o Viking Access Models L-3, F-1, T-21, H-10, B-12, Q-4
o Apollo 4300, 4500
Eberle Design, Inc. (EDI) provides access professionals with reliable, high quality
mission critical vehicle detection products that will improve the performance and
lifecycle of your access control systems.
EDI’s wide range of vehicle detection products help technicians save valuable time and
maximize profits by quickly installing, accurately trouble-
maintaining access control systems with easy to use hi-tech vehicle detectors that
provide built-in set-up tools, frequency & sensitivity meters, and non-volatile
diagnostic history, all of which are valuable and always available – Because they’re
built-in!
The front panel 7-segment LED DEFLECTOMETER
®
provides visual feedback and
assistance for setting the correct sensitivity, reading the frequency of the loop, reporting Loop
Faults, and indicating Delay & Extension Timing functions.
With a typical size vehicle over the roadway loop, the DEFLECTOMETER
®
functions as a
Sensitivity Meter. The optimum sensitivity setting should provide a reading of “5”. You can
adjust the DEFLECTOMETER
®
reading by using the front panel UP or DOWN sensitivity
buttons. Automatic quantitative feedback of the loop system operation ensures that the
detector is set to the most optimum sensitivity level to detect ALL vehicles, including
motorcycles and high-bed vehicles.
Following power-up or reset, the DEFLECTOMETER
®
will indicate a 2 or 3 digit number
(quickly flashes) that indicates the loop frequency of the loop & loop network. Keeping your
loops separated by at least 5 KHz avoids crosstalk problems and future service calls.
Ten (10) Levels of Sensitivity:
10 levels of sensitivity (0 to 9) can be easily set using the UP or DOWN push buttons.
One Model Covers ALL Low Voltages:
LMA-1800 operates on 12VDC, 24VDC, and 24VAC
Advanced Loop Diagnostics:
The Loop Fault Monitor continually checks the integrity of the loops and will report and store 3
types of loop faults; Open Loops, Shorted Loops, and 25% sudden changes in inductance.
The Loop Fault Memory uses internal Non-Volatile memory to store and display the current
and previous loop faults utilizing the front panel “Loop Fault” LED and DEFLECTOMETER
®
. A
power loss or reset will not delete this memory. A MUST FOR TROUBLESHOOTING!
The detector will not drop a Call state if power is lost for a minimum of 4 seconds or less.
2 Second Delayed Detection:
A 2-second CALL delay time can be provided via the program DIP switch.
Automatic Tuning - Lightning & Surge Protection - Four (4) Frequency Levels - Compatible with ALL radio controls & remote
openers - Sensitivity Boost - Fail Safe and Fail Secure Configurations - Separate Color-Coded LED indicators - Wide Loop
Inductance Range: 20 to 2500 micro Henries – Velcro pull tab for easy extraction from the rack